Fujitsu Healthy Living Implementation Guide
1.1.29 - release

Publication Build: This will be filled in by the publication tooling

ValueSet: Observation CGM Codes

Official URL: http://ig.fujitsu.com/healthy-living/ValueSet/observation-cgm-codes Version: 1.1.29
Active as of 2025-09-25 Computable Name: ObservationCgmValueSet

Codes representing items measured for alcohol consumption
CGMに関する持続グルコースモニタリング(CGM)を表すコード

References

Logical Definition (CLD)

  • Include these codes as defined in http://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codes
    CodeDisplayDefinition
    CGMCGM
    cgmSummaryCGM Summary ReportA summary of continuous glucose monitoring (CGM) data.
    cgmMeanGlucoseMassPerVolumeMean Glucose (Mass per Volume)The mean glucose value from a continuous glucose monitoring (CGM) summary, represented in mass units.
    cgmMeanGlucoseMolesPerVolumeMean Glucose (Moles per Volume)The mean glucose value from a continuous glucose monitoring (CGM) summary, represented in molar units.
    cgmDaysOfWearDays of WearThe number of days the continuous glucose monitoring (CGM) device was worn during the reporting period.
    cgmSensorActivePercentageSensor Active PercentageThe percentage of time the continuous glucose monitoring (CGM) sensor was active during the reporting period.
    cgmGmiGlucose Management Indicator (GMI)The Glucose Management Indicator (GMI) value from a continuous glucose monitoring (CGM) summary.
    cgmCvCoefficient of Variation (CV)The Coefficient of Variation (CV) value from a continuous glucose monitoring (CGM) summary.
    cgmTimesInRangesTimes in Glucose RangesContinuous glucose monitoring time in ranges panel
    cgmTimeInVeryLowTime in Very Low Range (%)Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent below target glucose range, very low (TBR-VL) <54 mg/dL (<3.0 mmol/L) (hypoglycemic) during reporting period.
    cgmTimeInLowTime in Low Range (%)Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent below target glucose range, low (TBR-L) 54-69 mg/dL (3.0-3.8 mmol/L) (hypoglycemic) during reporting period.
    cgmTimeInTargetTime in Target Range (%)Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent in target glucose range (70-180 mg/dL [3.9-10.0 mmol/L]) during reporting period.
    cgmTimeInHighTime in High Range (%)Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent above target glucose range, high (TAR-H) 181-250 mg/dL (10.1-13.9 mmol/L) (hyperglycemic) during reporting period.
    cgmTimeInVeryHighTime in Very High Range (%)Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent above target glucose range, very high (TAR-VH >250 mg/dL) (>13.9 mmol/L) (hyperglycemic) during reporting period.

 

Expansion

Expansion based on codesystem Observation PHR Codes v1.1.29 (CodeSystem)

This value set contains 14 concepts.

CodeSystemDisplayDefinition
  CGMhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesCGM
  cgmSummaryhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesCGM Summary Report

A summary of continuous glucose monitoring (CGM) data.

  cgmMeanGlucoseMassPerVolumehttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesMean Glucose (Mass per Volume)

The mean glucose value from a continuous glucose monitoring (CGM) summary, represented in mass units.

  cgmMeanGlucoseMolesPerVolumehttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesMean Glucose (Moles per Volume)

The mean glucose value from a continuous glucose monitoring (CGM) summary, represented in molar units.

  cgmDaysOfWearhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesDays of Wear

The number of days the continuous glucose monitoring (CGM) device was worn during the reporting period.

  cgmSensorActivePercentagehttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesSensor Active Percentage

The percentage of time the continuous glucose monitoring (CGM) sensor was active during the reporting period.

  cgmGmihttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesGlucose Management Indicator (GMI)

The Glucose Management Indicator (GMI) value from a continuous glucose monitoring (CGM) summary.

  cgmCvhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesCoefficient of Variation (CV)

The Coefficient of Variation (CV) value from a continuous glucose monitoring (CGM) summary.

  cgmTimesInRangeshttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesTimes in Glucose Ranges

Continuous glucose monitoring time in ranges panel

  cgmTimeInVeryLowhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesTime in Very Low Range (%)

Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent below target glucose range, very low (TBR-VL) <54 mg/dL (<3.0 mmol/L) (hypoglycemic) during reporting period.

  cgmTimeInLowhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesTime in Low Range (%)

Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent below target glucose range, low (TBR-L) 54-69 mg/dL (3.0-3.8 mmol/L) (hypoglycemic) during reporting period.

  cgmTimeInTargethttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesTime in Target Range (%)

Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent in target glucose range (70-180 mg/dL [3.9-10.0 mmol/L]) during reporting period.

  cgmTimeInHighhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesTime in High Range (%)

Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent above target glucose range, high (TAR-H) 181-250 mg/dL (10.1-13.9 mmol/L) (hyperglycemic) during reporting period.

  cgmTimeInVeryHighhttp://ig.fujitsu.com/healthy-living/CodeSystem/observation-phr-codesTime in Very High Range (%)

Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent above target glucose range, very high (TAR-VH >250 mg/dL) (>13.9 mmol/L) (hyperglycemic) during reporting period.


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code