Patient-Generated Health Data (PGHD) Implementation Guide
0.5.0 - release

Publication Build: This will be filled in by the publication tooling

: ECG Classification Codes - XML Representation

Active as of 2024-12-19

Raw xml | Download



<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="ecg-classification-codes"/>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p>このcase-sensitiveコードシステム <code>http://fhir/pghd/CodeSystem/ecg-classification-codes</code> は次のコードたちを定義します:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td><td><b>Japanese (ja)</b></td></tr><tr><td style="white-space:nowrap">sinusRhythm<a name="ecg-classification-codes-sinusRhythm"> </a></td><td>Sinus rhythm</td><td>The sample exhibits no signs of atrial fibrillation.</td><td>洞調律</td></tr><tr><td style="white-space:nowrap">atrialFibrillation<a name="ecg-classification-codes-atrialFibrillation"> </a></td><td>Atrial fibrillation</td><td>The sample exhibits signs of atrial fibrillation.</td><td>心房細動</td></tr><tr><td style="white-space:nowrap">inconclusiveHighHeartRate<a name="ecg-classification-codes-inconclusiveHighHeartRate"> </a></td><td>Inconclusive high heart rate</td><td>An unclassifiable sample caused by a rapid heart rate.</td><td>心拍数が120より上</td></tr><tr><td style="white-space:nowrap">inconclusiveLowHeartRate<a name="ecg-classification-codes-inconclusiveLowHeartRate"> </a></td><td>Inconclusive low heartrate</td><td>An unclassifiable sample caused by a heart rate below 50 bpm.</td><td>心拍数が50より下</td></tr><tr><td style="white-space:nowrap">inconclusivePoorReading<a name="ecg-classification-codes-inconclusivePoorReading"> </a></td><td>Inconclusive poor reading</td><td>An unclassifiable sample caused by an unclear signal.</td><td>判定不能</td></tr><tr><td style="white-space:nowrap">inconclusiveOther<a name="ecg-classification-codes-inconclusiveOther"> </a></td><td>Inconclusive other</td><td>An unclassifiable sample caused by an unknown issue.</td><td>その他</td></tr><tr><td style="white-space:nowrap">unrecognized<a name="ecg-classification-codes-unrecognized"> </a></td><td>Unrecognized</td><td>A sample classification that this version of HealthKit doesn’t recognize.</td><td>認識できない記録</td></tr><tr><td style="white-space:nowrap">notSet<a name="ecg-classification-codes-notSet"> </a></td><td>Not set</td><td>A sample that doesn’t have an assigned classification.</td><td>未設定</td></tr></table></div>
  </text>
  <url value="http://fhir/pghd/CodeSystem/ecg-classification-codes"/>
  <version value="0.5.0"/>
  <name value="EcgClassification"/>
  <title value="ECG Classification Codes"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2024-12-19T16:51:22+09:00"/>
  <description
               value="Codes for classification of ECG waveforms  
心電図波形の分類を表すコード"/>
  <copyright value="Copyright 2024+"/>
  <caseSensitive value="true"/>
  <compositional value="false"/>
  <content value="complete"/>
  <count value="8"/>
  <concept>
    <code value="sinusRhythm"/>
    <display value="Sinus rhythm"/>
    <definition value="The sample exhibits no signs of atrial fibrillation."/>
    <designation>
      <language value="ja"/>
      <value value="洞調律"/>
    </designation>
  </concept>
  <concept>
    <code value="atrialFibrillation"/>
    <display value="Atrial fibrillation"/>
    <definition value="The sample exhibits signs of atrial fibrillation."/>
    <designation>
      <language value="ja"/>
      <value value="心房細動"/>
    </designation>
  </concept>
  <concept>
    <code value="inconclusiveHighHeartRate"/>
    <display value="Inconclusive high heart rate"/>
    <definition
                value="An unclassifiable sample caused by a rapid heart rate."/>
    <designation>
      <language value="ja"/>
      <value value="心拍数が120より上"/>
    </designation>
  </concept>
  <concept>
    <code value="inconclusiveLowHeartRate"/>
    <display value="Inconclusive low heartrate"/>
    <definition
                value="An unclassifiable sample caused by a heart rate below 50 bpm."/>
    <designation>
      <language value="ja"/>
      <value value="心拍数が50より下"/>
    </designation>
  </concept>
  <concept>
    <code value="inconclusivePoorReading"/>
    <display value="Inconclusive poor reading"/>
    <definition
                value="An unclassifiable sample caused by an unclear signal."/>
    <designation>
      <language value="ja"/>
      <value value="判定不能"/>
    </designation>
  </concept>
  <concept>
    <code value="inconclusiveOther"/>
    <display value="Inconclusive other"/>
    <definition value="An unclassifiable sample caused by an unknown issue."/>
    <designation>
      <language value="ja"/>
      <value value="その他"/>
    </designation>
  </concept>
  <concept>
    <code value="unrecognized"/>
    <display value="Unrecognized"/>
    <definition
                value="A sample classification that this version of HealthKit doesn’t recognize."/>
    <designation>
      <language value="ja"/>
      <value value="認識できない記録"/>
    </designation>
  </concept>
  <concept>
    <code value="notSet"/>
    <display value="Not set"/>
    <definition
                value="A sample that doesn’t have an assigned classification."/>
    <designation>
      <language value="ja"/>
      <value value="未設定"/>
    </designation>
  </concept>
</CodeSystem>